Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Rev. colomb. ortop. traumatol ; 32(4): 215-219, 2018. ilus.
Article in Spanish | LILACS, COLNAL | ID: biblio-1373519

ABSTRACT

Introducción El objetivo del estudio es validar la versión corta de la escala de discapacidades de brazo, hombro y mano (QuickDASH) en español mediante pruebas de confiabilidad, consistencia y validez. Materiales y métodos Sobre 394 cuestionarios DASH de 298 sujetos participantes de un estudio previo, se corrieron pruebas de confiabilidad, consistencia, precisión, respuesta al cambio y validez. Resultados La confiabilidad medida mediante el coeficiente de concordancia de Lin fue de 0.8 IC95%: 0.67 a 0.93. La precisión transversal se estimó con intervalo de confianza de 95% en 12.72 y la precisión longitudinal (cambio mínimo detectable) se determinó en 20 puntos. Se obtuvo valores satisfactorios de capacidad de detectar respuesta al cambio y validez. Estas pruebas demostraron un comportamiento comparable entre el QuickDASH y el DASH ya validado en español. Discusión La versión abreviada de la escala perdió precisión tanto transversal como longitudinal debido a la disminución en la consistencia interna y en la estabilidad en la muestra estudiada, sin embargo conservó la capacidad de discriminar y de detectar cambio, estos resultados permiten recomendar su uso en ambiente clínico y de investigación. Nivel de Evidencia: II


Background aim of the study was to validate the short version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) in Spanish by testing reliability, consistency, and validity. Materials and methods A total of 394 DASH questionnaires, from 298 participants of a previous study, were tested for reliability, consistency, accuracy, validity and responsiveness to change. Results Reliability, measured by Lin concordance coefficient was 0.8, 95% CI: 0.67 to 0.93. Cross-sectional precision was estimated with a 95% confidence interval as 12.72, and longitudinal precision (minimum detectable change) was determined as 20 points. Satisfactory values regarding ability to detect response to change and validity were obtained. These tests showed comparable performance between QuickDASH and DASH and validated in Spanish. Discussion The shortened version of the scale lost both cross-sectional and longitudinal precision, due to the decrease in internal consistency and stability in the sample studied. As it retained the ability to discriminate and detect change, these results enable it to be recommended for use in the clinical and research setting. Evidence Level: II


Subject(s)
Humans , Upper Extremity
SELECTION OF CITATIONS
SEARCH DETAIL